Real-Time PCR System (FQS-16)

The FQS-16 Real-Time PCR System is a 16-well qPCR platform featuring four fluorescence channels: FAM/SYBR Green I, HEX/JOE/VIC, ROX/Texas Red, and Cy5. Powered by Peltier-based thermal cycling technology, it offers a compact design weighing just 5.8 kg, a detection sensitivity of 1 copy, and excellent repeatability (CV ≤ 3%). The system is compatible with four-color multiplex PCR kits and is suitable for diagnostic laboratories, livestock farms, shrimp aquaculture facilities, and mobile laboratories.

PRODUCT CATEGORY

Real-Time PCR System (FQS-16)

Real-Time PCR System (FQS-16) is a compact 16-well qPCR system featuring four fluorescence channels. Weighing just 5.8 kg and equipped with Peltier-based thermal cycling technology, it is suitable for both laboratory and field applications.

Máy Real-time PCR (FQS-16) 16 giếng 4 kênh huỳnh quang


Product Overview

The Real-Time PCR System (FQS-16) is an ideal solution for laboratories and field teams seeking a compact, cost-effective qPCR system capable of performing multicolor multiplex PCR. The system supports both quantitative Real-Time PCR analysis and melting curve analysis, including High-Resolution Melting (HRM), subject to assay compatibility.

It is suitable for pathogen detection in livestock and aquaculture , including ASFV, WSSV, and EHP, as well as molecular diagnostics and scientific research.


Key Features

  • Compact and Portable Design: Dimensions of 324 × 212 × 138 mm and a maximum weight of 5.8 kg, making it suitable for use at livestock farms, shrimp farms, veterinary stations, and mobile laboratories.
  • Four Independent Fluorescence Channels: Supports FAM/SYBR Green I, HEX/JOE/VIC, ROX/Texas Red, and Cy5, enabling compatibility with four-color multiplex PCR assays.
  • Peltier-Based Semiconductor Thermal Cycling: Gia nhiệt và làm lạnh nhanh, giúp chu trình nhiệt chính xác và lặp lại tốt.
  • Short Run Time: Under the same thermal cycling program, the FQS-16 completes runs approximately 10 minutes faster than the Bioer 96 system.
  • Reliable Reproducibility and Stability: Evaluation across more than 180 reactions showed that most CV values were below 3% between runs and below 2% across independent testing days.
  • High Analytical Sensitivity: Detects as little as 1 copy, with a linear dynamic range of 1 to 10¹⁰ copies.
  • Comprehensive, User-Friendly Software:
    • Configure thermal cycling programs, assign samples and fluorescence channels, monitor runs, and analyze results.
    • View raw results and analyzed data, including intuitive amplification curves.
    • Includes preconfigured run-program templates for ABT kits.
    • Automatically adjusts the temperature according to the actual sample volume in the tube, eliminating the need for manual volume entry.
    • Function: File Readback helps recover the most recent run data if the connection is interrupted.
  • Intuitive Error Alerts: Six status LEDs provide visual system feedback. The Error indicator and audible alarm alert users to block temperature sensor malfunctions.
  • Convenient Sample Handling: Compatible with individual 0.2 mL PCR tubes and 8-tube strips.

Máy Real-time PCR (FQS-16) 16 giếng 4 kênh huỳnh quang


Specification

ParameterFQS-16 Specifications
ModelFQS-16
Sample Capacity16 wells × 0.2 mL
Compatible ConsumablesIndividual PCR tubes (0.2 mL) / 8-tube strips (0.2 mL)
Sample volume5 – 100 µL
Linear Dynamic Range1–10¹⁰ copies
Fluorescent channelsCH1: FAM / SYBR Green I; CH2: HEX / JOE / VIC; CH3: ROX / TexasRed; CH4: CY5
Light SourceHigh-brightness, long-life LED
Đầu dòPhotodiode sensor
Sensitivity1 copy
ResolutionFluorescence acquisition repeatability: CV ≤ 3%; fluorescence acquisition accuracy: CV ≤ 5%; Ct value repeatability: CV ≤ 3%
Block Temperature RangeBlock: 10–99.9°C; Heated lid: 30–105°C
Thermal Cycling TechnologyPeltier / Semiconductor refrigeration
Temperature AccuracyBlock temperature control accuracy: ≤ ±0.5°C; heated lid temperature accuracy: ≤ ±5°C; temperature holding time accuracy: ±5%
Maximum Heating/Cooling RateHeating rate: ≥ 1.6°C/s; cooling rate: ≥ 1.5°C/s
PC Operating SystemWindows 7 / Windows 10
ConnectivityRS232 / USB
Data AnalysisQuantitative analysis; Melting Curve / HRM; Baseline & Threshold; Baseline Correction; S-Curve Correction; Crosstalk Elimination; Standard Curve
Electricity supplyAC 100 – 240V~, 50 / 60Hz
Maximum Power Consumption300VA
Dimensions (W × D × H)324 × 212 × 138 mm
WeightMax. 5.8 kg

Application

  • Mobile and Field Laboratories: Ideal for livestock farms, shrimp farms, and veterinary stations requiring lightweight, portable equipment.
  • Small and Medium-Sized Laboratories: An affordable investment for laboratories needing reliable performance with four-color multiplex assays.
  • Replacement of Older Equipment: Suitable for laboratories experiencing block heating or fluorescence signal issues with older qPCR systems.
  • Veterinary and Aquaculture Diagnostics: Detection of ASFV (African swine fever virus), WSSV, and EHP in shrimp; multiplex testing using four-color kits.

Compatibility with ABT qPCR Kits

The system has been evaluated with the following ABT TopSPEC® kits:

Compared with the Bioer 96 system, amplification curves across the FAM, HEX, Texas Red, and Cy5 channels show comparable profiles and stable signals across replicate runs. Both systems demonstrate comparable differentiation between positive and negative samples.


PC System Requirements

  • Operating System: Windows 7 or Windows 10
  • CPU: 2 GHz or higher (minimum 1.6 GHz)
  • RAM: Minimum 2 GB; 4 GB recommended
  • Hard Disk: At least 4.5 GB of free space
  • Display: Minimum resolution of 1280 × 768; 1920 × 1080 recommended. A laptop with a 15.6-inch display or larger is recommended to view all four channels, especially Cy5.
  • Software: .NET Framework 4.0 or later; install the USB driver (Windows_CDM21228_Setup).

Usage Recommendations

  • Install the software on a drive other than C: (e.g., D:) to avoid COM connection errors.
  • Use a laptop with a 15.6-inch display or larger. Smaller displays may require scaling adjustments.
  • If a COM connection error occurs after several runs, reconnect the COM cable or restart the software before the next run. If a run is interrupted, use Help → File Readback to recover the data.
  • When comparing results with another system, use the same analysis method and threshold settings, as Ct values may differ slightly. The FAM channel may show Ct values approximately 1.13 cycles higher.
  • Operate the instrument at an ambient temperature of 10–30°C, on a clean, flat surface, with at least 20 cm of clearance for heat dissipation. Do not obstruct the ventilation openings.

Why Choose the Real-Time PCR System (FQS-16)?

  • Compact and portable, ideal for field testing.
  • Four fluorescence channels, supporting multiplex PCR kits.
  • High sensitivity with excellent repeatability and stability.
  • Short run times to reduce testing time.
  • Comprehensive English-language software with built-in templates for ABT kits.

Manual instruction

Vietnamese 

English 

Video

Catalog

Vietnamese 

English 

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Công ty TNHH giải pháp y sinh ABT

ABT BIOLOGICAL SOLUTIONS COMPANY LIMITED

ABT is a pioneering biotechnology company specializing in advanced diagnostic solutions that support disease prevention and safeguard public health. With a global vision, ABT continuously invests in research and development to enhance product quality and affirm the scientific standing of Vietnam on the international stage.

Contact us

Factory 6.07 and 5.02, Lot L2, Long Hau – Hiep Phuoc Road, Long Hau Industrial Park, Can Giuoc Commune, Tay Ninh Province, Vietnam

No. 1 and No. 3, 13B Street, An Lac Ward, Ho Chi Minh City, Vietnam

0903 307 258
028 2216 0885

oversea@abtvn.com

Scroll to Top